Properdin, Human, ELISA kit – 1 x 96 det. - HK334-01
Quantity
1 x 96 det.
Catalog #
HK334-01
778,00 €
Properdin is a cornerstone glycoprotein in the alternative complement pathway. Anchoring the immune response, Properdin predominantly circulates as dynamic trimers, vital for stabilizing the C3bBb complex. This key role not only amplifies the body's defense mechanism but also significantly prolongs the lifespan of immune complexes.
Properdin deficiencies, passed down as X-linked traits, range from complete inactivity to dysfunctional forms, crucially influencing the immune system's effectiveness. With levels varying between 5 to 25 μg/mL in healthy individuals, Properdin emerges as a critical biomarker in immune regulation research, especially in conditions like diabetes. Properdin has the potential of giving new insights in immunological studies and therapeutic developments.
Datasheet URL | https://www.hycultbiotech.com/wp-content/uploads/2022/06/HK334-1223.pdf |
---|---|
Quantity | 1 x 96 det. |
Quantity | 1 x 96 det. |
Standard range | 0.31 to 20 ng/ml |
Detection level | 0.31 ng/ml |
Working volume | 100 µl/well |
Species | human |
Cross reactivity | Cynomolgus monkey - Yes, Goat - No, Horse - No, Mouse - Yes, Pig - Yes, Rabbit - Weak, Rat - No, Sheep - No |
Application | The human Properdin ELISA kit is to be used for the in vitro quantitative determination of human Properdin in serum, plasma, bronchoalveolar lavage fluid, urine and cerebrospinal fluid samples. |
Principle | The human Properdin ELISA is a ready-to-use solid-phase enzyme-linked immunosorbent assay based on the sandwich principle with a working time of 3½ hours. The efficient format of a plate with twelve disposable 8-well strips allows free choice of batch size for the assay. Samples and standards are incubated in microtiter wells coated with antibodies recognizing human Properdin. Biotinylated tracer antibody will bind to the captured human Properdin. Streptavidin-peroxidase conjugate will bind to the biotinylated tracer antibody. Streptavidin-peroxidase conjugate will react with the substrate, tetramethylbenzidine (TMB). The enzyme reaction is stopped by the addition of oxalic acid. The absorbance at 450 nm is measured with a spectrophotometer. A standard curve is obtained by plotting the absorbance (linear) versus the corresponding concentrations of the human Properdin standards (log). The human Properdin concentration of samples, which are run concurrently with the standards, can be determined from the standard curve. |
Storage and stability | Product should be stored at 4 °C. Under recommended storage conditions, product is stable for at least six months. |
Precautions | For research use only. Not for use in or on humans or animals or for diagnostics. It is the responsibility of the user to comply with all local/state and Federal rules in the use of this product. Hycult Biotech is not responsible for any patent infringements that might result with the use or derivation of this product. |
References | 1. Harboe, M et al; The Role of Properdin in Zymosan- and Escherichia coli-Induced Complement Activation. J Immunol 2012, 189: 2606 |
Disease | Autoimmunity |
Application assays: | The human Properdin ELISA kit is to be used for the in vitro quantitative determination of human Properdin in serum, plasma, bronchoalveolar lavage fluid, urine and cerebrospinal fluid samples. |
---|---|
Principle: | The human Properdin ELISA is a ready-to-use solid-phase enzyme-linked immunosorbent assay based on the sandwich principle with a working time of 3½ hours. The efficient format of a plate with twelve disposable 8-well strips allows free choice of batch size for the assay. Samples and standards are incubated in microtiter wells coated with antibodies recognizing human Properdin. Biotinylated tracer antibody will bind to the captured human Properdin. Streptavidin-peroxidase conjugate will bind to the biotinylated tracer antibody. Streptavidin-peroxidase conjugate will react with the substrate, tetramethylbenzidine (TMB). The enzyme reaction is stopped by the addition of oxalic acid. The absorbance at 450 nm is measured with a spectrophotometer. A standard curve is obtained by plotting the absorbance (linear) versus the corresponding concentrations of the human Properdin standards (log). The human Properdin concentration of samples, which are run concurrently with the standards, can be determined from the standard curve. |
Perfomance: | The linearity of the assay was determined by serially diluting a serum. The line obtained a correlation coefficient of 0.9966 |
Recovery: | Normal human blood samples (plasma) containing baseline levels of human Properdin, were spiked with human Properdin, in concentrations of 500 and 2000 ng/ml. Samples with and without human Properdin, were incubated for 1 hour at room temperature. Samples were measured using the ELISA. Values for human Properdin, ranged between 85.1% and 115.3%. |